24/7 emergency service. Call now
PlumbPro Plumbing and Heating, West Warwick RI
Contact Us

The Heat Went Out at 2am: What to Do First

The house is getting cold and the boiler or furnace is silent.

The PlumbPro team · November 9, 2026

  • Licensed since 2017
  • Residential & commercial
  • 24/7 for emergencies

Go through these checks in order, then decide whether to call tonight or in the morning.

Safety first

If none of those apply, work through the checks below. Each one takes about a minute, and none of them involve opening up the equipment.

The checks, in order

  1. Look at the thermostat

    Make sure it's set to heat, the setting is above room temperature, and the screen is on. If the display is blank or dim, put in new batteries. A smart thermostat may have lost its schedule or slipped into away mode.

  2. Check the power switch and breaker

    Most boilers and furnaces have an emergency switch, often a red plate at the top of the basement stairs or near the unit. It looks like a light switch and gets turned off by accident all the time. Check it, then check the heating breaker in your panel.

  3. Check the fuel

    On oil, read the gauge on top of the tank. A tank that's nearly empty can stop feeding the burner before it reads zero. On gas, see if the stove or water heater works; if nothing gas-fired works, the problem is the supply and the gas utility is the call.

  4. Press the reset once, and only once

    Oil burners have a red reset button on the burner control. If one press gets it running and it stays running, you may be fine until morning, but book service, because it shut down for a reason. If it doesn't start, don't press it again: repeated resets can flood the chamber with oil that lights all at once.

  5. Take a photo of any error code

    Many newer gas boilers and furnaces show a code or blink a light when they shut down. A photo of it helps whoever comes out.

  6. Read the boiler pressure

    On a hot water boiler, most home systems sit around 12 to 15 psi when cold. A reading near zero usually means the boiler shut itself off on low water, often from a leak somewhere in the system.

  7. Look at the vent pipes outside

    High-efficiency units vent through plastic pipes on the side of the house, and drifting snow can block them. If you can reach them safely from the ground, clear the snow away.

What not to do

  • Don't keep pressing the reset button.
  • Don't take panels off or bypass any switch or safety control.
  • Don't heat the house with the oven or a gas range.
  • Don't run a generator, grill or camp heater inside or in an attached garage.
  • Don't leave a space heater running unattended or near curtains, bedding or furniture.

Getting through until morning

Close the doors to rooms you aren't using and keep everyone in one room, with a space heater if you have one and use it carefully. Open the cabinet doors under sinks on outside walls, and let a faucet on an outside wall drip.

If a line has already frozen, our post on preventing frozen pipes covers what to do next.

Call tonight or wait until morning?

Call now if

  • It's below freezing and the house is cooling fast
  • There's a baby, an older adult or anyone with a medical condition at home
  • Water is leaking from the boiler or heating pipes
  • The house will be empty and unheated for the next day

It can probably wait if

  • It's mild out and the house is holding in the low 60s
  • You can keep one room warm safely
  • There's no leak, smell or alarm

No heat on a cold night is an emergency, and we answer around the clock for it. If it can safely wait until morning, we'll tell you that too. Our emergency plumbing page explains how night calls work.

Have this ready when you call

  • Boiler or furnace, and whether it's oil, gas or propane
  • The make and rough age, if you know them
  • What you checked and what happened
  • Any error code or light pattern
  • Whether you see water, smell anything or hear odd noises

Photos of the unit and its label help a lot.

What happens when we get there

We repeat the safety checks, then work through the system until we find the cause. The usual suspects are a failed igniter or flame sensor, a bad circulator, a clogged nozzle or filter on an oil burner, or a failed control.

Before we replace anything, we tell you what we found and what the repair costs. If an older boiler is pointing to a bigger problem, you can get the heat back on tonight and plan a boiler replacement later.

More detail is on our no-heat service, boiler repair and, for forced air, furnace pages. We cover West Warwick, Warwick, East Greenwich and the towns around them.

Not sure what you need?

Describe what you’re seeing and we’ll tell you whether it’s a quick fix or a bigger job.

Call us
Call 401-773-5000